Transmittance curves, which show that both coatings on glass present good transmission in the visible spectrum (400 to 700nm), and both block the infrared.

Reflectance curves, which show that, in the infrared, the polymeric film (P70) is basically absorptive, whereas the metal-dielectric coating (LX70) is reflective - this allows the IR energy co-utilization for the air conditioning system through the building envelope.